DATAKOM DPR-02 is (Original) and made in Turkey. It is a specialized protection relay designed to monitor and safeguard three-phase systems against:

  • Over-voltage: When voltage exceeds safe operational limits, which can cause overheating and insulation failure in equipment.
  • Under-voltage: When voltage drops below the operational threshold, leading to equipment malfunction or failure.
  • Phase Sequence Errors: Protection against incorrect wiring or phase reversal.
  • Phase Loss: Detection and prevention of damage caused by one phase becoming inactive.

(Note: Bulk quantity pricing often differs from unit prices.)

Quantity

Description

DATAKOM DPR-02 is a specialized protection relay designed to monitor and safeguard three-phase systems against:

  • Over-voltage: When voltage exceeds safe operational limits, which can cause overheating and insulation failure in equipment.
  • Under-voltage: When voltage drops below the operational threshold, leading to equipment malfunction or failure.
  • Phase Sequence Errors: Protection against incorrect wiring or phase reversal.
  • Phase Loss: Detection and prevention of damage caused by one phase becoming inactive.

Design and Construction:

Enclosure:

  • High-grade ABS/PC (polycarbonate blend) ensures durability, heat resistance, and compliance with UL94-V0 flame-retardant standards.
  • Compact design for efficient DIN rail mounting, saving space in electrical panels.

Front Panel:

Adjustable trimmers for configuring:

  • Over-voltage limit.
  • Under-voltage limit.
  • Trip delay.
  • Reset delay.

LED indicators:

  • ON: Shows power status.
  • OUT: Indicates relay activation.
  • U<: Under-voltage warning.
  • U>: Over-voltage warning.

Advanced Functional Features:

Voltage Monitoring and Protection:

  • Measures line-to-line voltages using True RMS (Root Mean Square) technology, ensuring accurate detection even in the presence of distorted waveforms or harmonics.

Adjustable Limits:

Allows users to configure operational voltage ranges:

  • Over-voltage: From 240V to 300V.
  • Under-voltage: From 150V to 210V.

Protection can be disabled for specific scenarios by adjusting trimmers to their limit positions.

Time Delays:

Prevents nuisance trips due to transient disturbances:

  • Trip Delay (0.5-20 seconds): Ensures only sustained faults trigger the relay.
  • Reset Delay (0.5-20 seconds): Allows time for the system to stabilize before reactivating.

Phase Sequence and Loss Detection:

  • Detects incorrect phase order and disables relay output to prevent motor damage or system failure.
  • Monitors for phase absence or disconnection and provides early warnings.

Fail-Safe Operation:

  • Automatically disables relay outputs in fault conditions, ensuring the connected equipment remains protected.

Applications:

Power Generation:

  • Protects alternators and generators from voltage irregularities and phase issues.

Industrial Motors:

  • Prevents damage to three-phase motors from running in reverse or under incorrect voltage conditions.

Transformers:

  • Safeguards against insulation stress and overheating caused by voltage abnormalities.

Capacitor Banks:

  • Monitors voltage levels to prevent overloading or poor performance in power factor correction systems.

Distribution Panels:

  • Ensures stable voltage supply and prevents faults from propagating through the system.

Technical Specifications:

Electrical Characteristics:

  • Nominal Voltage: 230V AC (line-to-neutral).
  • Voltage Range: 150-300V AC.
  • Measurement Method: True RMS.
  • Frequency Range: 47-63 Hz.
  • Power Consumption: Maximum 30 VA / 2 W.

Relay Output:

Configuration:

  • SPDT (Single Pole Double Throw).

Rating:

  • AC: 6A at 277V.
  • DC: 6A at 30V.

Switching Power:

  • 1800 VA (AC).
  • 300 W (DC).

Environmental Ratings:

  • Operating Temperature: -30°C to +70°C.
  • Storage Temperature: -40°C to +80°C.
  • Humidity: Up to 95% (non-condensing).
  • EMI/RFI Resistance: Complies with international standards for electromagnetic compatibility.

Physical Dimensions:

  • Width: 36 mm.
  • Height: 90.6 mm.
  • Depth: 58.4 mm.
  • Weight: Approximately 100 grams.

Compliance:

CE Certification:

  • Ensures conformity with safety, health, and environmental protection standards.

EU Directives:

  • Low Voltage (2006/95/EC).
  • Electromagnetic Compatibility (2004/108/EC).

Installation:

Mounting:

  • DIN Rail: Standard 35 mm rail mounting for quick and secure installation.

Wiring:

  • Input phase voltage terminals must be connected with fast-acting (FF) 6A fuses for protection.
  • Recommended cable size: 0.75 mm² to 1.5 mm² (AWG18-16).

Environment:

  • Avoid installation near high-EMI devices or in high-vibration zones.
  • Ensure proper ventilation around the device to maintain optimal operating temperature.

Testing:

  • After installation, verify all connections and test the relay by simulating fault conditions (over-voltage, under-voltage, phase sequence reversal).

 